discontinue use.
The update period of data is less than 5 seconds, which is changeable according to different
individual pulse rate.
Please read the measured value when the waveform on screen is equably and steady-going,This
measured value is optimal value. And the waveform at the monment is the standard one.
If some abnormal conditions appear on the screen during test process, pull out the finger and
reinsert to restore normal use.
The device has normal useful life for three years since the first electrified use.
The hanging rope attached the product is made from Non- allergy material, if particular group
are sensitive to the hanging rope, stop using it. In addition, pay attention to the use of the
hanging rope , do not wear it around the neck avoiding cause harm to the patient.
The instrument dose not have low-voltage alarm function, it only shows the low-voltage . please
change the battery when the battery energy is used out.
When the parameter is particularly, The instrument dose not have alarm function . Do not use the
device in situations where alarms are required.
Batteries must be removed if the device is going to be stored for more than one month , or else
batteries may leak.
A flexible circuit connects the two part s of the device . Do not twist or pull on the connection.
1.4
1.4
1.4
1.4 Indication
Indication
Indication
Indication for
for
for
for Use
Use
Use
Use
The Fingertip Pulse Oximeter is a non-invasive device intended for the spot-check of oxygen
saturation of arterial hemoglobin (SpO
2
) and the pulse rate of adult and pediatric patients in home
and hospital environments (including clinical use in internist/surgery, anesthesia, intensive care
ect.). This device is not intended for continuous monitoring.
2
2
2
2 O
O
O
O verview
verview
verview
verview
The pulse oxygen saturation is the percentage of HbO
2
in the total Hb in the blood, so-called the O
2
concentration in the blood. It is an important bio-parameter for the respiration. For the purpose of
measuring the SpO
2
more easily and accurately, our company developed the Pulse Oximeter. At the
same time, the device can measure the pulse rate simultaneously.
The Pulse Oximeter features in small volume, low power consumption, convenient operation and
being portable. It is only necessary for patient to put one of his fingers into a fingertip photoelectric
sensor for diagnosis, and a display screen will directly show measured value of Hemoglobin
Saturation.
2.1
2.1
2.1
2.1 Classification
Classification
Classification
Classification
Class II b , ( MDD93/42/EEC IX Rule 10 )
2.2
2.2
2.2
2.2 Features
Features
Features
Features
Operation of the product is simple and convenient.
The product is small in volume, light in weight (total weight is about 50 g including batteries)
and convenient in carrying.
Power consumption of the product is low and the two originally equipped AAA batteries can be
operated continuously for 20 hours.
The product will automatically be powered off when no signal is in the product within 5